About HV variable frequency drive (6kV or 10kV/11kV)
Product Features
High-high direct high-voltage power supply: high-voltage variable frequency drive has high-voltage direct input and high-voltage direct output, without the need for output step-up transformers. The equipment occupies a small area and is suitable for ordinary AC induction motors;
High efficiency: The efficiency of high-voltage variable frequency drive can reach over 96%;
High power factor: The power factor of the high-voltage variable frequency drive can reach 0.95 or above;
No harmonic input: The high-voltage variable frequency drive uses phase-shifting multiple rectification technology for input, resulting in low voltage and current harmonics. There is no need to add harmonic control devices for input, which does not cause pollution to the power grid;
No harmonic output: The high-voltage variable frequency drive outputs standard sine wave current, with low voltage and current harmonics. The output does not require the addition of harmonic compensation devices, does not increase the operating noise of the motor, and does not generate additional stress;
High reliability: The high-voltage variable frequency drive has automatic fault bypass and high-voltage power outage restart functions, ensuring that the motor does not stop running in case of faults;
High safety: The design of the high-voltage variable frequency drive follows the mandatory high-voltage national regulations, and the optical fiber connection between the high-voltage main circuit and the control circuit is safe and reliable;
Complete protection and fault alarm design: The high-voltage variable frequency drive is equipped with complete system protection functions and power unit protection functions. After various protection actions, it can achieve automatic fault recording and accident memory. Fault recording can automatically record the types and times of various protection actions, helping technical personnel analyze the cause of faults and locate them;
High flexibility: The high-voltage variable frequency drive is controlled on-site through PLC, and the control mode can be flexibly changed by modifying parameter settings through the human-machine interface. It has multiple standard communication protocols to facilitate communication with the central control system;
Convenient installation, commissioning, and maintenance: The power unit is designed in the form of a drawer, and the power unit and external wiring are connected through connectors, without the need for manual wiring. It has good interchangeability and is easy to replace.
Comprehensive Motor Control for Demanding ApplicationsDesigned for versatility, the HV-VFD-6kV-11kV series excels in controlling pumps, compressors, conveyors, and blowers in sectors like power generation, mining, oil & gas, and water supply. Its drive type supports both direct and bypass soft start options, ensuring gentle motor acceleration, extended lifespan, and reduced mechanical stress.
Efficient and Reliable Operation with Minimal MaintenanceThe drives self-diagnostic system, alarm/event logging, and built-in harmonic suppression contribute to a robust, low-maintenance solution. With forced air or optional water cooling, it maintains peak efficiency above 96%, while overload capability and phase sequence protection secure dependable operation under variable load conditions.
Flexible Integration and CustomizationSupporting modern industrial protocols (RS485, Modbus, Ethernet, Profibus), this HV drive integrates effortlessly with existing automation systems. Options for touchscreen HMI or LCD panels, customizable IP ratings, and factory-available spare parts kits allow tailored deployment to meet specific operational and environmental requirements.
FAQs of HV variable frequency drive (6kV or 10kV/11kV):
Q: How is the HV-VFD-6kV-11kV series installed, and where should it be located?
A: Installation should be floor-mounted in an indoor environment, following the manufacturers guidelines provided in the manual. A standard configuration measures 3800 x 1400 x 2450 mm, but dimensions can be customized. Proper ventilation and easy access for maintenance are recommended.
Q: What protection and safety features does this drive offer?
A: This model includes phase sequence protection, overload capability (150% for 60 seconds), soft start/stop, and a high-voltage isolation transformer. The enclosure can be configured up to IP54 for effective dust and water ingress protection, ensuring high safety and reliability.
Q: How does the harmonic suppression work and what are its benefits?
A: Integrated harmonic suppression ensures that power quality meets IEC 61800-3 standards. This reduces harmonic distortion that could otherwise damage equipment or disrupt sensitive processes. The benefit is improved operational stability and extended motor life.
Q: What communication and control options are available for remote operation?
A: The drive supports multiple interfaces such as RS485, Modbus, Ethernet, and optional Profibus, enabling integration into SCADA or DCS for remote monitoring and control. A touchscreen HMI or LCD panel is provided for local operation and status display.
Q: When and how can maintenance or troubleshooting be performed?
A: The HV-VFD includes a self-diagnostic system, built-in event and alarm history, and supports low-maintenance operation. For troubleshooting, technicians can utilize the control panel to access logs and status information. Spare parts kits are available upon request.
Q: What is the recommended process for selecting the cooling method?
A: Cooling is typically by forced air, but water cooling can be selected for higher power ratings or challenging ambient conditions. The choice depends on the installation environment, required power capacity, and available infrastructure. Consult with the supplier for optimal configuration.